HOME   |   ABOUT US   |   PRODUCTS   |   SERVICES   |   CONTACT US
 
 
  laxven
Digital Notch Indicator

The Digital Notch Indicator developed by M/s Laxven Systems is a Micro Controller based for use in Electric Locomotives to indicate the position of notch engaged, in seven segment digital form in both the cabs of the locomotive to the driver. The system also has indications for half notch struck up below or above the notch position and DJ trip indication (with notch indication where the DJ trip took place). This digital notch indicator can be used for both ABB/ GANZ type.

 

The events like DJ trip, Half Notch struck up, Power ON, Power off Conditions are stored in memory with real date & time stamp in a non volatile memory. The system can store up to 10000 events (First In First Out). This data can be down loaded to the computer with special software developed by M/s Laxven systems.

 

The Digital Notch indicator is provided with CAN BUS to share the information of the notch position with other electronic devices having CAN BUS facility, working on the locomotive.

Digital Notch Indicator

Digital Notch Indicator

The system is powered from DC voltages available in the locomotive. For Electric Locomotive, it is suitable for the voltage variations between 70V DC to 140V DC.

 

The mounting positions of the transmitter and indicators are exactly maintained as that of ECIL’s transmitter & indicators for interchanging and retro-fitment. The same wiring and numbering is maintained to avoid confusion among the shed staff while installation and commissioning.

 

The Digital Notch Indicator conforms to the RDSO specifications. Laxven has also developed the test equipment and calibration tools to calibrate the Microcontroller based digital notch indicator.

  • Highly Accurate, stable and reliable Microcontroller based System
  • Less Maintenance and long reliability
  • Self diagnostic and fail safe Microcontroller based System
  • Highly accurate measurement of angle (0.01 degree measurement)
  • System can be used with ABB/GANZ tap changers
  • Highly reliable and accurate synchro transmitter.
  • Two digit LED display of One inch size for better viewing of the notch indication
  • Half notch indication and recording enables the loco crew to identify the problems in the tap changer.
  • Alignment of synchro transmitter electrical null point with tap changer null position can be done very easily
  • Power supply can work from 50V to 140V DC and can be used on any Indian railway locomotive.
  • Switch mode power supply provided with built in protection for Reverse Polarity, Input over Voltage, Over Current and Short Circuit. High capacity filters provided for Surge/Transient suppression and EMI/EMC suppression.
  • Events are recorded with date & time stamp in a non-volatile memory for post analysis.
  • 10000 events recording in FIFO manner
  • User configurable parameter entry through Laptop
  • Mounting and dimensions are similar to the existing system.
  • CANBUS provided for data communication with other micro processor based systems
  • Downloading of data using RS232 port.
  • User friendly and powerful Analysis software for post analysis of data
  • Downloaded data can be converted to Excel file format
Power Supply voltage : 50 to 140 V DC from loco battery
Power : Less than 12 Watts
Accuracy of Angle : 0.01 degree
Notch Measurement : Through Synchro transmitter
Tap changer selection : Through Selector switch provided under lock
Null alignment of
Synchro
: Through push to ON switch provided under lock
Recording System : 10000 events recorded with date & time stamp in FIFO manner in Non-volatile memory
Recording of events :

1) Power ON/OFF

2) DJ Trip indication

3) Half notch struck up

4) Zero setting of synchro transmitter

5) Internal faults

Display : 2 x 1 inch seven segment LED display for notch indication and 1 inch UP & DOWN arrow seven segment LED display
for Half notch indication
LED Indications : LED indications are provided for DJ Trip, ABB/GANZ selection and internal faults
Temperature range : -5 deg. C to + 80 deg. C
Data Entry : Through laptop
Downloading of
Recorded Data
: Data can be downloaded to PC using RS232
Communication with
other systems
: Through CAN 2.0 protocol
Analysis Software : Windows based Powerful and user friendly software

Manual

Qu

laxven
Copyright © 2009 Laxven Systems., All Rights Reserved.